EGT (pyrometer) amplifier · Type K thermocouple · 0 – 5 V analog out

EG5 and EG12 specifications

The output side is the same three wires as any pressure sensor — supply, ground, signal — so it wires into any analog input and calibrates with two points. Sold as the module alone: the probe and the bung it threads into are bought separately, to the specifications under Recommended to use with.

Specifications

EG5 · EG12
ParameterEG5EG12
SensorType K thermocouple, ungroundedType K thermocouple, ungrounded
Range0 – 960 °C0 – 1250 °C
Output5 mV/°C4 mV/°C
Zero0.000 V = 0 °C0.000 V = 0 °C
Supply5 V — the ECU's sensor rail8 – 16 V switched, 12 V nominal
Input protectionDirect inputSeries limits, RC filter and clamp diodes on both legs
Initial accuracy±3 °C at 25 °C±3 °C at 60 °C
Size36.3 × 27.5 × 15.6 mm, 51.1 mm long over the zip-tie saddles, ASA-CF44 × 34 × 16.1 mm, 58.8 mm long over the zip-tie saddles, ASA-CF

Output cable: red supply · black ground · yellow signal. Thermocouple cable: yellow + · red −. Both are cut square, the ends not stripped.

Download the datasheet (PDF) Full specifications · wiring · calibration · fitting notes

Setup guides: wiring and software setup for Speeduino, MegaSquirt, Haltech, Link, AEM, Holley EFI, MaxxECU and more.